The total solar energy captured was very close to previous months report, so it has been quite bright outside of lately. I think the days are starting to get shorter, so soon I think we will see the number drop. But for now I expect to stay over 3 Megawatt hours of production a month unless we have a bunch of storms. We are in a really bad drought right now, so it has been quite the opposite of that. I guess good for the solar panels but hard on everything else around here.
Art commissioned by
@takuri
Mining hardware: 2x Bitmain Antminer S21 Pros running at 7800 watts. Cooled using AC Infinity inline fans.
Array A production stats:
Load: 2380 kWh
PV: 412.6 kWh
Grid Import: 2090.1 kWh
Battery Charge: 132.8 kWh
Battery Discharge: 11.6 kWh
Array A build:
System Size = 5.5 kWp DC
Panels = Sungoldpower Monocryalline 60 cell (12 Panels, 450 Watts each)
Mounting System = Brightmount EG4 screwed into 6x6 timbers
Wiring: 1x 8 AWG 19 strand PV direct bury wire pair
Inverters = 2x Sol-Ark 15k all-in-ones (240V)
Battery Backup = 48 3.2v EVE LF280 LiFePO4 280AH batteries
Battery Management system = Daly Smart BMS 16S 48V 500A
Battery Capacity = 45.696 kWh (840AH)
Propane Generator = Briggs and Stratton Power Protect 26kw
Array B production stats:
Load: 2311.6 kWh
PV: 841.2 kWh
Grid Import: 1572.8 kWh
Battery Charge: 181.6 kWh
Battery Discharge: 146.3 kWh
Array B build:
System Size = 9 kWp DC
Panels = Sungoldpower Monocrystalline 60 cell (20 Panels, 450 Watts each)
Mounting System = Brightmount EG4 screwed into 6x6 timbers
Wiring: 2x 8 AWG 19 strand PV direct bury wire pair
Inverters = Sol-Ark 15k all-in-one (240V)
Battery Backup = 48 3.2v LiFePO4 290AH batteries (unknown brand)
Battery Management system = Daly Smart BMS 16S 48V 250A
Battery Capacity = 47.328 kWh (870AH)
Propane Generator = Briggs and Stratton Power Protect 22kw
Array C production stats:
Load: 1835.6 kWh
PV: 2031.5 kWh
Grid Import: 0 kWh
Battery Charge: 495.7 kWh
Battery Discharge: 568.4 kWh
Array C build:
System Size = 14 kWp DC
Panels = Eco-worthy Bifacial 190W 2 strings of 48 panels running at 275v each and 1 string of 12 440W Sungoldpower N-Type solar panels running at 401v
Mounting System = 36 Eco-worthy Multi-panels mounts
Wiring: 3x 8 AWG 19 strand PV direct bury wire pair
Inverters = Sol-Ark 15k all-in-one (240V)
Battery Backup = 6x Pytes V5 batteries
Battery Management system = Built in Pytes BMS
Battery Capacity = 30 kWh (600AH)
@solominer/solos-solar-array-production-stats-july-2026
@solominer/solos-solar-array-production-stats-june-2026
@solominer/solos-solar-array-production-stats-may-2026
@solominer/solos-solar-array-production-stats-april-2026
@solominer/solos-solar-array-production-stats-march-2026
@solominer/solos-solar-array-production-stats-february-2026
@solominer/solos-solar-array-production-stats-january-2026
@solominer/solos-solar-array-production-stats-december-2025
@solominer/solos-solar-array-production-stats-november-2025
@solominer/solos-solar-array-production-stats-october-2025
@solominer/solos-solar-array-production-stats-september-2025
@solominer/solos-solar-array-production-stats-august-2025
@solominer/solos-solar-array-production-stats-july-2025
@solominer/solos-solar-array-production-stats-june-2025
@solominer/solos-solar-array-production-stats-may-2025
@solominer/solos-solar-array-production-stats-april-2025
@solominer/solos-solar-array-production-stats-march-2025
@solominer/solos-solar-array-production-stats-february-2025
@solominer/solos-solar-array-production-stats-january-2025
@solominer/solos-solar-array-production-stats-december
@solominer/solos-solar-array-production-stats-november
@solominer/solos-solar-array-production-stats-october
@solominer/solos-solar-array-production-stats-september
@solominer/solos-solar-array-production-stats-august