With a good amount of snow coming around last month we lost solar on the days I did not remove the snow. Only array C did I clear off the panels, as it was truly off grid and needed to recover power during the day. The other array I just left covered until it melted on its own. So we indeed lost a few days of productivity by that. Even with the snow removed from array-C it only barely made more than the A+B so I think it was just a pretty cloudy month in general.
It has also been mostly cloudy, only with a few days of full sun. Many times I find myself charging my electric vehicle during that time instead of mining. But I think during the summer I should have more power produced, and the battery powered machines are more efficient during the summer as warmer temperatures make the batteries run better.
Array A production stats:
Load: 1996.7 kWh
PV: 234.7 kWh
Grid Import: 1882.8 kWh
Battery Charge: 117.6 kWh
Battery Discharge: 100.6 kWh
Array A build:
System Size = 5.5 kWp DC
Panels = Sungoldpower Monocryalline 60 cell (12 Panels, 450 Watts each)
Mounting System = Brightmount EG4 screwed into 6x6 timbers
Wiring: 1x 8 AWG 19 strand PV direct bury wire pair
Inverters = 2x Sol-Ark 15k all-in-ones (240V)
Battery Backup = 48 3.2v EVE LF280 LiFePO4 280AH batteries
Battery Management system = Daly Smart BMS 16S 48V 500A
Battery Capacity = 45.696 kWh (840AH)
Propane Generator = Briggs and Stratton Power Protect 26kw
Array B production stats:
Load: 1234.6 kWh
PV: 561.1 kWh
Grid Import: 777.6 kWh
Battery Charge: 302.6 kWh
Battery Discharge: 256.2 kWh
Array B build:
System Size = 9 kWp DC
Panels = Sungoldpower Monocrystalline 60 cell (20 Panels, 450 Watts each)
Mounting System = Brightmount EG4 screwed into 6x6 timbers
Wiring: 2x 8 AWG 19 strand PV direct bury wire pair
Inverters = Sol-Ark 15k all-in-one (240V)
Battery Backup = 48 3.2v LiFePO4 290AH batteries (unknown brand)
Battery Management system = Daly Smart BMS 16S 48V 250A
Battery Capacity = 47.328 kWh (870AH)
Propane Generator = Briggs and Stratton Power Protect 22kw
Array C production stats:
Load: 500.3 kWh
PV: 606 kWh
Grid Import: 0 kWh
Battery Charge: 243.8 kWh
Battery Discharge: 218.4 kWh
Array C build:
System Size = 9 kWp DC
Panels = Eco-worthy Bifacial 190W (2 strings of 48 panels running at 275v each)
Mounting System = 12 Eco-worthy Multi-panels mount holds four panels each.
Wiring: 2x 8 AWG 19 strand PV direct bury wire pair
Inverters = Sol-Ark 15k all-in-one (240V)
Battery Backup = 3x Pytes V5 batteries
Battery Management system = Built in Pytes BMS
Battery Capacity = 15 kWh (272AH)
@solominer/solos-solar-array-production-stats-november-2025
@solominer/solos-solar-array-production-stats-october-2025
@solominer/solos-solar-array-production-stats-september-2025
@solominer/solos-solar-array-production-stats-august-2025
@solominer/solos-solar-array-production-stats-july-2025
@solominer/solos-solar-array-production-stats-june-2025
@solominer/solos-solar-array-production-stats-may-2025
@solominer/solos-solar-array-production-stats-april-2025
@solominer/solos-solar-array-production-stats-march-2025
@solominer/solos-solar-array-production-stats-february-2025
@solominer/solos-solar-array-production-stats-january-2025
@solominer/solos-solar-array-production-stats-december
@solominer/solos-solar-array-production-stats-november
@solominer/solos-solar-array-production-stats-october
@solominer/solos-solar-array-production-stats-september
@solominer/solos-solar-array-production-stats-august