Hopefully as we enter the spring we stay above the 2 megawatt hour range. But you never know when some cloudy days may show up, or a tropical storm passes through. But April was a good start to another productive month in storing and using solar power.
Soon I should have Array-C fully built out, and troubleshooting is still ongoing with the one string that is acting up. Next I plan on running an above ground pair of 8 gauge wire to the splitters and back to the inverter. So I can isolate that below ground cable. If all works with the new cable I know its somewhere underground causing the problem. Also it was mentioned probing the ground near the suspected damage after recent rains with a multimeter may find stray voltage if there is a damaged wire underground. It could show up as just a couple volts, or not work at all. But with so little rain I think it would just be easier to a new temporary cable to test with.
Mining hardware: 2x Bitmain Antminer S21 Pros running at 7200 watts. Only one was in use for April due to array issues.
Array A production stats:
Load: 1926.2 kWh
PV: 385.3 kWh
Grid Import: 1664 kWh
Battery Charge: 120.7 kWh
Battery Discharge: 90.5 kWh
Array A build:
System Size = 5.5 kWp DC
Panels = Sungoldpower Monocryalline 60 cell (12 Panels, 450 Watts each)
Mounting System = Brightmount EG4 screwed into 6x6 timbers
Wiring: 1x 8 AWG 19 strand PV direct bury wire pair
Inverters = 2x Sol-Ark 15k all-in-ones (240V)
Battery Backup = 48 3.2v EVE LF280 LiFePO4 280AH batteries
Battery Management system = Daly Smart BMS 16S 48V 500A
Battery Capacity = 45.696 kWh (840AH)
Propane Generator = Briggs and Stratton Power Protect 26kw
Array B production stats:
Load: 1671.4 kWh
PV: 1070.8 kWh
Grid Import: 793.9 kWh
Battery Charge: 517.5 kWh
Battery Discharge: 434.1 kWh
Array B build:
System Size = 9 kWp DC
Panels = Sungoldpower Monocrystalline 60 cell (20 Panels, 450 Watts each)
Mounting System = Brightmount EG4 screwed into 6x6 timbers
Wiring: 2x 8 AWG 19 strand PV direct bury wire pair
Inverters = Sol-Ark 15k all-in-one (240V)
Battery Backup = 48 3.2v LiFePO4 290AH batteries (unknown brand)
Battery Management system = Daly Smart BMS 16S 48V 250A
Battery Capacity = 47.328 kWh (870AH)
Propane Generator = Briggs and Stratton Power Protect 22kw
Array C production stats:
Load: 508 kWh
PV: 615.7 kWh
Grid Import: 0 kWh
Battery Charge: 223.2 kWh
Battery Discharge: 198.5 kWh
Array C build:
System Size = 9 kWp DC
Panels = Eco-worthy Bifacial 190W (2 strings of 48 panels running at 275v each)
Mounting System = 12 Eco-worthy Multi-panels mount holds four panels each.
Wiring: 2x 8 AWG 19 strand PV direct bury wire pair
Inverters = Sol-Ark 15k all-in-one (240V)
Battery Backup = 6x Pytes V5 batteries
Battery Management system = Built in Pytes BMS
Battery Capacity = 30 kWh (600AH)
@solominer/solos-solar-array-production-stats-march-2026
@solominer/solos-solar-array-production-stats-february-2026
@solominer/solos-solar-array-production-stats-january-2026
@solominer/solos-solar-array-production-stats-december-2025
@solominer/solos-solar-array-production-stats-november-2025
@solominer/solos-solar-array-production-stats-october-2025
@solominer/solos-solar-array-production-stats-september-2025
@solominer/solos-solar-array-production-stats-august-2025
@solominer/solos-solar-array-production-stats-july-2025
@solominer/solos-solar-array-production-stats-june-2025
@solominer/solos-solar-array-production-stats-may-2025
@solominer/solos-solar-array-production-stats-april-2025
@solominer/solos-solar-array-production-stats-march-2025
@solominer/solos-solar-array-production-stats-february-2025
@solominer/solos-solar-array-production-stats-january-2025
@solominer/solos-solar-array-production-stats-december
@solominer/solos-solar-array-production-stats-november
@solominer/solos-solar-array-production-stats-october
@solominer/solos-solar-array-production-stats-september
@solominer/solos-solar-array-production-stats-august